{"id":204,"date":"2019-03-12T12:15:31","date_gmt":"2019-03-12T11:15:31","guid":{"rendered":"https:\/\/www.bttautomatyka.pl\/?page_id=204"},"modified":"2019-03-12T12:21:03","modified_gmt":"2019-03-12T11:21:03","slug":"wysokoobrotowe-silniki-indukcyjne","status":"publish","type":"page","link":"https:\/\/www.bttautomatyka.pl\/index.php\/wysokoobrotowe-silniki-indukcyjne\/","title":{"rendered":"Wysokoobrotowe silniki indukcyjne"},"content":{"rendered":"\ufeff\n<div class=\"btt highspeed floatfix\">\n  <h1>High-Speed three-phase squirrel cage induction motor(s). For IGBT- converter operation<\/h1>\n  <h2>Drive for a driven machine with following technical data:<\/h2>\n  \t<table>\n\t\t<tr>\n\t\t\t<td>Kind of driven machine : <\/td>\n\t\t\t<td>test bench<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Power demand of driven machine : <\/td>\n\t\t\t<td>250kW at speed 4766 rpm<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Speed range : <\/td>\n\t\t\t<td>4766-15000rpm<\/td>\n\t\t<\/tr>\n\t<\/table>\n  <h2>Product code: HMP 250-2 Motor data at converter operation<\/h2>\n  \t<table>\n\t\t<tr>\n\t\t\t<td>Duty : <\/td>\n\t\t\t<td>S1<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Frame size : <\/td>\n\t\t\t<td>250<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Thermal class : <\/td>\n\t\t\t<td>155 (F)<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Cooling temperature range : <\/td>\n\t\t\t<td>+5 to + 40\u00b0C<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Type of construction : <\/td>\n\t\t\t<td>IM B35<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Cooling method : <\/td>\n\t\t\t<td>IC 06<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Degree of protection : <\/td>\n\t\t\t<td>IP 23<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Installation : <\/td>\n\t\t\t<td>indoor<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Type of coupling : <\/td>\n\t\t\t<td><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Sense of rotation (viewed on DE) : <\/td>\n\t\t\t<td>bidirectional<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Type of bearing : <\/td>\n\t\t\t<td>anti-friction, grease lubricated (Spindle bearings)<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Site altitude above sea level : <\/td>\n\t\t\t<td>&le;1000m<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Weight : <\/td>\n\t\t\t<td>approx. 750kg<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Mass moment of inertia : <\/td>\n\t\t\t<td>0.29kg.m&sup2;<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Paint system \/ color shade : <\/td>\n\t\t\t<td>W \/ RAL 7015<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Outline drawing-no. (preliminary) : <\/td>\n\t\t\t<td><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Terminal box location (viewed on DE) : <\/td>\n\t\t\t<td>right or left<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Terminal box : <\/td>\n\t\t\t<td>main terminal box with 3 threaded holes M72x2, with ble glands<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Cable entry location (viewed on DE) : <\/td>\n\t\t\t<td>from below<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Standards : <\/td>\n\t\t\t<td>EN 60034-1, EN 60034-2<\/td>\n\t\t<\/tr>\n\t<\/table>\n  <h2>Accessories\/special Information<\/h2>\n  \t<table>\n\t\t<tr>\n\t\t\t<td>Temperature monitoring for winding : <\/td>\n\t\t\t<td>3 Pt100 (3 wires connection) from terminal<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Temperature monitoring for bearing : <\/td>\n\t\t\t<td>1 Pt100 \/ bearing (3-wire-connection)<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>with encoder mounted on NDE : <\/td>\n\t\t\t<td>Heidenhain \/ Germany product code ROD 436 HTL; line counts 1024 ppr<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Bearing insulation with DE mounted forced ventilation, supply voltage shaft end DE without keyway : <\/td>\n\t\t\t<td>400V 50Hz<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>flange coupling : <\/td>\n\t\t\t<td>without<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>locking device : <\/td>\n\t\t\t<td>without<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>Vibration velocity : <\/td>\n\t\t\t<td>&le; 2,8mm\/s throughout the speed range, decoupled foundation, during run-out<\/td>\n\t\t<\/tr>\n\t<\/table>\n  <p>With automatic regreasing device (external control must be provided)<\/p>\n  <p>Voltage stress at frequency converter<\/p>\n  \t<table>\n\t\t<tr>\n\t\t\t<td>max rate of voltage rise dv\/dt : <\/td>\n\t\t\t<td>5kV \/ &micro;s<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>max. peak voltage at motor terminals : <\/td>\n\t\t\t<td>1350 V<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td>switching frequency : <\/td>\n\t\t\t<td>&ge; 2.5 kHz<\/td>\n\t\t<\/tr>\n\t<\/table>\n  <img src=\"\/BTT\/img\/highspeed_torque.png\" >\n  <img src=\"\/BTT\/img\/highspeed_power.png\" >\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/page_fullwidth.php","meta":{"_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.bttautomatyka.pl\/index.php\/wp-json\/wp\/v2\/pages\/204"}],"collection":[{"href":"https:\/\/www.bttautomatyka.pl\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.bttautomatyka.pl\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.bttautomatyka.pl\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bttautomatyka.pl\/index.php\/wp-json\/wp\/v2\/comments?post=204"}],"version-history":[{"count":1,"href":"https:\/\/www.bttautomatyka.pl\/index.php\/wp-json\/wp\/v2\/pages\/204\/revisions"}],"predecessor-version":[{"id":205,"href":"https:\/\/www.bttautomatyka.pl\/index.php\/wp-json\/wp\/v2\/pages\/204\/revisions\/205"}],"wp:attachment":[{"href":"https:\/\/www.bttautomatyka.pl\/index.php\/wp-json\/wp\/v2\/media?parent=204"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}